JH Solar Version 1: 7 kW, 16.38 kWh All-in-One Solar Unit
Last checked · JH Solar guide

JH Solar Version 1 is our smaller all-in-one solar unit: a 7 kW hybrid inverter, a solar charger and a 16.38 kWh LiFePO4 battery in one floor-standing cabinet on casters. The unit price is ₱120,000. It is built for homes that want steady night and brownout backup without filling the roof with panels.
This page covers the full specifications, how its single solar input works, what it can run, its honest limits, how it is wired and placed, and how to order. Every number is either a rated figure or a worked example labelled “Example”, with the math shown.

What JH Solar Version 1 Is
JH Solar Version 1 joins three parts that are usually sold as separate boxes: a hybrid inverter that turns battery and solar DC into 230 V AC for your outlets, an MPPT solar charger, and a lithium iron phosphate battery. Because they share one cabinet, there are no external battery cables to run between boxes, and the inverter and battery are already matched.
It is plug-and-play in that sense: the hard pairing work is done inside. It is also a floor-standing unit on casters that can be moved, which makes it the step up from a hand-carry power station. The panels still go on your roof, and a licensed electrician still connects the unit to your panel board. Our Version 1 and Version 2 comparison shows how it sits next to the larger model.
The unit works with or without grid power. When Meralco or your electric cooperative has a brownout, it keeps the loads on its output running from the battery, and the panels keep charging during the day.
Who JH Solar Version 1 Suits
JH Solar Version 1 suits households where the main goal is backup at night and during brownouts, not covering a large daytime bill. Its big battery is the strong point. Its single solar input, which takes up to six panels, is the part that sets the ceiling.
- Smaller homes: lights, fans, a refrigerator, a TV, Wi-Fi, laptops and phone charging, with aircon used only some hours.
- Night and brownout backup: families in areas with frequent outages who want the fridge, lights and fans to keep going after dark.
- Limited roof space: homes that can fit about six large panels but not twelve or more.
- Small shops: a sari-sari store or home office that needs lights, a chiller and a laptop to survive outages.
If you run two or more aircon units during the day or want to cut a large bill, the larger JH Solar Version 2 with dual MPPT inputs is usually the better match. The quickest way to see which side you are on is to run your electric bill through our solar computation tool, which shows your daily kWh and every assumption.
JH Solar Version 1 Price: ₱120,000 for the Unit
Unit price
₱120,000
Unit only; panels, mounting, wiring, labor and permits are quoted after a site assessment.
People often ask “magkano ang JH Solar Version 1?” The unit is ₱120,000. That buys the cabinet with the 7 kW inverter, the solar charger and the 16.38 kWh battery inside. It does not include the panels or the work around them.
The rest depends on your house: roof type, cable distance and permit fees all differ, so we quote those parts after a site assessment.
Full Specifications
These are the rated figures for JH Solar Version 1. Use them to compare against your loads and roof, and keep this table handy when you read your quote.
| Item | Rating |
|---|---|
| Type | All-in-one: inverter + MPPT solar charger + LiFePO4 battery in one cabinet |
| Inverter output | 7 kW, 230 V AC, pure sine wave |
| Battery | 16.38 kWh nominal, 51.2 V, 320 Ah, LiFePO4 |
| Solar input | 4,480 W max PV input, one MPPT |
| MPPT voltage range | 60–140 V DC |
| Max PV open-circuit voltage | 180 V |
| Max solar charging current | 80 A |
| Panels per string | Up to 3 in series (180 V limit) |
| Typical array | 6 × 620 W in 3S2P = 3.72 kWp (6 × 720 W = 4.32 kWp) |
| Mounting | Floor-standing on casters |
Dimensions and weight are confirmed with your quote. Battery kWh is nominal; the energy that reaches your appliances is lower (see the examples below).
Two numbers matter most when you plan. The 7 kW inverter rating is how much power the unit can deliver at once, and the 16.38 kWh battery is how much energy it stores. Mixing up kW and kWh is the most common sizing mistake, so read how home batteries are sized for nominal versus usable kWh.
How the Solar Input Works: One MPPT and the 3S2P Layout
JH Solar Version 1 has one solar input with one maximum power point tracker (MPPT). The tracker works between 60 V and 140 V, accepts up to 4,480 W of panel power, and must never see more than 180 V open-circuit.
Why three panels in series is the maximum
Panels in series add their voltage. Our 620 W panel is rated 48.6 V open-circuit and 41.3 V at maximum power. Three in series give about 145.8 V open-circuit and 123.9 V while working, which sits inside the MPPT window and under the 180 V limit. Four in series would reach about 194.4 V, and panel voltage climbs even higher on cool, bright mornings, so a fourth panel is never added.
Two strings in parallel
To use six panels, the installer builds two strings of three and joins them in parallel. This is called 3S2P. Parallel strings add current while keeping the voltage of one string.
| Layout | Panels | Array size | Fits the input? |
|---|---|---|---|
| 3S2P with 620 W panels (standard package) | 6 × 620 W | 3.72 kWp | Yes, under the 4,480 W input |
| 3S2P with 720 W panels | 6 × 720 W | 4.32 kWp | Yes, close to the input rating |
| 4 panels in one string | 4 in series | — | No: about 194.4 V open-circuit with 620 W panels, over 180 V |
| More than 6 panels | 7 or more | — | Not a standard layout; look at Version 2 instead |
The 720 W panel's electrical data is confirmed with your quote. Strings must also pass the input's current limits, which your installer checks against the manual.

The Honest Limit: Recharging 16.38 kWh From Six Panels
Here is the trade-off with Version 1. The battery is large, but the solar input is modest, so a fully drained battery is hard to refill in one day. Plan around it rather than be surprised later.
Example: even if the input ran at its full 4,480 W for a 3-hour midday peak, that is 4,480 W × 3 h = 13.44 kWh, still less than 16.38 kWh. With the standard 3.72 kWp package and 20% losses, the same 3 hours give about 3.72 × 3 × 0.8 ≈ 8.9 kWh. The charging current caps out too: Example: 80 A × 51.2 V ≈ 4.1 kW into the battery at most.
Across a whole sunny day the panels give more than the peak window alone. Example: 3.72 kWp × 4 peak sun hours × 0.75 overall factor ≈ 11.2 kWh. Daytime appliances use part of that before it reaches the battery. On rainy-season days, expect less.
In practice, JH Solar Version 1 works best when night use is moderate, so the battery is only partly drained by morning, or when the grid tops it up between outages.
What JH Solar Version 1 Can Run
Two checks decide whether JH Solar Version 1 fits your loads. First, power: add up the watts of everything that runs at the same moment, plus the start-up surge of motors like a fridge compressor or aircon, and keep it under 7 kW. Second, energy: add up watts × hours for each appliance and divide by 1,000 to get kWh.
| Example load | Example watts × hours | Example energy |
|---|---|---|
| LED lights (8 bulbs × 10 W) | 80 W × 6 h | 0.48 kWh |
| Two electric fans | 120 W × 8 h | 0.96 kWh |
| Inverter-type refrigerator (average draw) | 100 W × 12 h | 1.2 kWh |
| TV | 100 W × 4 h | 0.4 kWh |
| Wi-Fi router | 15 W × 12 h | 0.18 kWh |
| Example total without aircon | — | ≈ 3.2 kWh |
| Add: 1HP inverter aircon | 800 W × 8 h | 6.4 kWh |
| Example total with aircon | — | ≈ 9.6 kWh |
Example wattages only. Use the labels on your own appliances; real draw changes with settings, heat and age.
Example: the battery delivers about 16.38 kWh × 0.8 usable × 0.9 efficiency ≈ 11.79 kWh to your appliances. The night without aircon uses less than a third of that. The night with one aircon fits, but leaves little margin, and the six panels then need most of a sunny day to put it back.
For aircon users, an inverter-type unit set at a moderate temperature is much easier on the battery than an old non-inverter one. Our guide to solar inverter limits explains why motor start-up surge matters when you pick what to keep on the backup output.

Typical Wiring Summary
A Version 1 install follows a standard layout. This summary is for understanding your quote, not a do-it-yourself guide: the AC side and the panel board connection are work for a licensed electrician.
- Panels: two strings of three panels (3S2P), with mounting rated for the wind in your area.
- String fuses: each string gets its own fuse, because two strings are joined in parallel and a fault in one string could otherwise push current back through it.
- DC isolator: a switch between the panels and the unit so the solar side can be shut off for service.
- Surge protection: a DC surge protective device on the solar line, which matters in a country with frequent thunderstorms.
- AC breaker: sized from the rated output current of about 30.4 A at 230 V (roughly 30 A). A licensed electrician picks the final breaker and cable size from the manual and the Philippine Electrical Code.
- Grounding: the panel frames, rails and cabinet are bonded to a proper ground.
Electrical work in the Philippines is done by a registered master electrician or a professional electrical engineer; the Institute of Integrated Electrical Engineers of the Philippines publishes the Philippine Electrical Code they follow.
Where to Place the Unit
The battery and inverter last longer when they stay cool and dry.
- Ventilation: a shaded, dry area with airflow, out of direct afternoon sun, with open space around the cabinet as the manual specifies.
- Flood level: above the highest water your street has seen, on a raised base if needed.
- Away from LPG: keep it away from LPG tanks, the kitchen, fuel, paint and anything that burns easily.
- Short cable runs: near the panel board where possible, to limit cable length and losses.
Philippine Conditions and Tips on Your Phone
Peak sun hours in the Philippines are typically about 3.5 to 5 a day, depending on place and season. You can look up your own city on the Global Solar Atlas. During the rainy season, output can stay low for days, which is when grid top-ups and careful load choices matter most for a six-panel system.
Heat also matters: panels lose some output on hot afternoons, and batteries age faster when they run hot. Typhoon season calls for mounting that suits local wind and a check after a strong storm.
On your phone
- Before you photograph your bill, hide your name, address and Customer Account Number (CAN), and keep the kWh line readable.
- Take roof photos in daylight from the ground, and a photo of the spot where the cabinet could stand.
- Photograph the labels of your fridge and aircon so the watts are on record.
- Save the quote, the shutdown steps and the warranty terms in one folder.
How to Order JH Solar Version 1
Ordering JH Solar Version 1 follows five steps, and nothing is final until you accept a written quote.
Step 1: Compute your needs
Enter your bill’s kWh in the solar computation tool to see your daily use and a rough system size.
Step 2: Send your bill
Hide your name, address and Customer Account Number (CAN) before you take the photo; we only need the kWh used, the billing period and the amount. Then send the bill photo, your city or barangay and the loads you want backed up, through the form on our contact page or on Messenger.
Step 3: Site assessment
We check the roof, shade, the spot for the cabinet, the distance to your panel board and your wiring.
Step 4: Written quote
You get the unit, panel count, parts list, price and warranty terms in writing. Ask anything first.
Step 5: Installation
Licensed electricians install the panels, protection devices and unit, test it, and show you how it works.
If you would rather talk first, the contact page for quotes and site assessments lists what to send and what happens next.
Payment Methods and Warranty
Payment methods we accept: Bank transfer, GCash, Maya, Cash. The payment terms for your order are written into your quote, so you know what is due and when before you pay anything. Keep every receipt with your quote.
For Version 1, the warranty terms are written into your quote. Before you sign, ask what is covered, how a claim is made, and who you call if the display shows an error during a brownout.
JH Solar Version 1 Customer Reviews
No published reviews yet.
We publish reviews only from real JH Solar customers, with their permission, after their system has been running for a while. Already have a JH Solar Version 1? Write a review with the form below or share it on our Facebook page.
JH Solar on FacebookCustomers can share their own review with the form above; each review appears on this page after JH Solar checks it.
Safety and Electrical Reminders
- Do not open the cabinet. The battery stays live even when the grid and the panels are off.
- Never add a fourth panel to a string. Going over 180 V open-circuit can damage the solar input.
- Switch off the DC isolator before anyone touches the panel wiring; panels make voltage whenever light hits them.
- Keep the unit away from LPG tanks, water and flammable items, with open space for airflow.
- After a flood or typhoon, do not touch wet equipment. Have a licensed electrician check the system before it is switched back on.
Solar panels make DC power whenever light hits them, and batteries hold enough energy to start a fire if they are shorted. Work on the grid side, the AC panel board or a net-metered system belongs to a licensed electrical practitioner following the Philippine Electrical Code. Our numbers are estimates, not a design or a quote.
Frequently Asked Questions
Can JH Solar Version 1 run a 1HP aircon through the night?
It can power one inverter-type 1HP aircon, since its 7 kW inverter has room for that load plus a fridge and lights. The battery is the real limit. Example: an aircon averaging 800 W for 8 hours uses 6.4 kWh, which is more than half of the roughly 11.79 kWh the battery delivers to loads. Add your other night loads before you decide, and check that the panels can refill it the next day.
Why does Version 1 allow only three panels in each string?
Its solar input accepts at most 180 V open-circuit. Three 620 W panels in series give about 145.8 V at standard test conditions, and voltage rises further on cool mornings. A fourth panel would reach about 194.4 V before any cold correction, which is over the limit and can damage the charger. That is why the package uses two strings of three panels joined in parallel.
Can I connect more than six panels to Version 1?
Not as a standard layout. The single MPPT input is rated for 4,480 W, and six 720 W panels already reach 4.32 kWp, close to that ceiling. More panels would push the array past the input rating, so extra panels add cost without adding much charging. If your home needs a bigger array, Version 2 with its two MPPT inputs is the unit to look at instead.
Does the ₱120,000 price of Version 1 include the solar panels?
No. The ₱120,000 is for the all-in-one unit alone. Panels, mounting rails, PV cables, DC and AC protection, labor and permits are quoted separately after a site assessment, because roof type, cable distance and permit needs change from house to house. Your written quote lists each item so you can see what you are paying for before you agree.
Will Version 1 still work if my area loses grid power for several days?
Yes, it is rated to work with or without grid power, so the panels keep charging the battery during a long outage and the battery runs your loads at night. During several cloudy days, though, the six panels may not refill the battery each day. In a long outage, cut back to essential loads such as the fridge, lights, fans and phone charging.
How many hours can a full Version 1 battery last in a brownout?
It depends on the load. Example: 16.38 kWh × 0.80 usable × 0.90 efficiency ≈ 11.79 kWh reaches your appliances. At a steady 500 W, such as a fridge, fans, lights and a TV, that is about 23.6 hours. At a steady 1 kW it is about 11.8 hours. These are example assumptions, and real runtime changes with heat, battery age and how the loads cycle.
Conclusion: Is JH Solar Version 1 Right for Your Home?
JH Solar Version 1 packs a 7 kW inverter and a 16.38 kWh battery into one cabinet for ₱120,000, unit only. It shines as night and brownout backup for smaller homes, with a modest six-panel array in a 3S2P layout. Its honest limit is the single 4,480 W solar input, which cannot refill a fully drained battery in one short peak.
Start with your bill, check your night loads against the examples above, and send us the details for a site assessment. You can also read more about JH Solar and our other guides on the homepage.
See if Version 1 fits your home
Compute your daily kWh from your bill, then send it to us for a site assessment and a written quote.
Related Guides
- JH Solar HomeStart here: JH Solar systems and every guide on one page.
- JH Solar ProductsOur two all-in-one units, side by side.
- JH Solar Version 211 kW, dual MPPT and 15.36 kWh for aircon homes.
- Solar ComputationTurn your electric bill into a system size in a few taps.
- Contact JH SolarAsk for a quote or a site assessment.
- Solar Battery GuideHow much battery you need for nights and brownouts.